Written by Administrator
|
|
Thursday, 29 October 2009 11:38 |
|
Several research projects are ongoing in cooperation with the eye clinic at the University Hospital of Umeå. We are at the end of an ISO-standard study to complete the CE regulatory demands. A cross linking study recently began to evaluate possibility to detect biomechanical properties with the ART sensor technology. A two year follow-up of LASEK treated eyes will be completed in beginning of 2010, showing that the sensor perform on reshaped corneas. |
|
Written by Administrator
|
|
Wednesday, 04 June 2008 01:00 |
Background information about our research and our products BioResonator is based on the patents that resulted from joint research by Professor Sadao Omata and co-workers in Japan, and professor Olof Lindahl and co-workers at Umeå University in Sweden. BioResonators core technology is a resonating sensor made out of piezoelectric ceramics. The R&D team has been, and still are, an active part of the development of the resonance technology, including the scientific verification of the technology and part of product development within the field of IOP-measurement. The Research group has published more than one hundred scientific papers. BioResonator have a wide range of experience in:
- Basic research
- Applied research
- Product development
- Building prototypes
- Industrial productification
- Commercialisation of medical devices
Selected references
- Hallberg, P., Eklund, A., Backlund, T. & Linden, C. (2007). Clinical Evaluation of Applanation Resonance Tonometry: A Comparison With Goldmann Applanation Tonometry . J Glaucoma 16, 88-93 .
- Hallberg, P., Eklund, A., Santala, K., Koskela, T., Lindahl, O. & Linden, C. (2006). Underestimation of intraocular pressure after photorefractive keratectomy: a biomechanical analysis. Med Biol Eng Comput 44, 609-18 .
- Hallberg, P., Linden, C., Lindahl, O. A., Backlund, T. & Eklund, A. (2004). Applanation resonance tonometry for intraocular pressure in humans. Physiol Meas 25, 1053-65 .
- Eklund, A., Hallberg, P., Linden, C. & Lindahl, O. A. (2003). An applanation resonator sensor for measuring intraocular pressure using combined continuous force and area measurement. Investigative Ophthalmology & Visual Science 44, 3017-24 .
- Eklund, A., Linden, C., Backlund, T., Andersson, B. M. & Lindahl, O. A. (2003). Evaluation of applanation resonator sensors for intra-ocular pressure measurement: results from clinical and in vitro studies. Medical & Biological Engineering & Computing 41, 190-7 .
- Eklund, A., Backlund, T. & Lindahl, O. A. (2000). A resonator sensor for measurement of intraocular pressure--evaluation in an in vitro pig-eye model. Physiological Measurement 21, 355-67 .
- Eklund, A., Bergh, A. & Lindahl, O. A. (1999). A catheter tactile sensor for measuring hardness of soft tissue: measurement in a silicone model and in an in vitro human prostate model. Medical and Biological Engineering and Computing 37, 618-24.
Future Applications
|
|
Last Updated on Sunday, 30 August 2009 15:36 |
|
Read more...
|
|
|
|
|
|
|
|